表2-1 梁重力荷载标准值
层次 构件 b×h(m2) g=bhγ
n Gi ∑Gi
kN/m (m) (kN) (kN)
1-6层 KL1(6) 0.3×0.5 3.75 2.6 1 9.750 68.625
3.8 2 28.500
2 1 7.500
2.9 1 10.875
3.2 1 12.000
KL2(7) 0.3×0.5 3.75 3.2 1 12.000 69.188
0.25×0.5 3.125 2.6 1 8.125
3.8 2 23.750
2 1 6.250
2.9 1 9.063
3.2 1 10.000
KL3(6) 0.25×0.5 3.125 3.2 2 20.000 68.438
2.6 1 8.125
5.0 2 31.250
2.9 1 9.063
KL4(6) 0.3×0.5 3.75 3.2 2 24.000 82.125
2.6 1 9.750
5.0 2 37.500
2.9 1 10.875
KL5(2) 0.3×0.5 3.75 1.7 1 6.375 22.875
4.4 1 16.500
KL6(3) 0.3×0.5 3.75 4.7 1 17.625 36.688
0.25×0.5 3.125 1.7 1 5.313
4.4 1 13.750
KL7(3) 0.25×0.5 3.125 4.7 1 14.688 33.755
KL11(3) 1.7 1 5.313
4.4 1 13.750
KL8(1) 0.25×0.5 3.125 4.7 2 29.315 29.375
KL9(2) 0.25×0.5 3.125 1.9 1 5.938 19.688
4.4 1 13.750
KL10(3) 0.25×0.5 3.125 4.7 1 14.688 33.751
1.7 1 5.313
4.4 1 13.750
KL12(3) 0.3×0.5 3.75 4.7 1 17.625 40.5
1.7 1 6.375
4.4 1 16.500
L1 0.25×0.4 2.5 4.2 2 21.000 64.5
L2 0.25×0.4 2.5 2.1 2 10.500
L3 0.25×0.4 2.5 4.8 2 24.000
L4 0.25×0.4 2.5 1.8 2 9.000
∑Gi 603.255
表2-2 柱重力荷载标准值
层次 构件 b× (m×m) g=bhγ (kN/m) (m) n G (kN)
女儿墙 Z 0.2×0.2 1 0.6 17 10.2
6 Z 0.4×0.4 4 1.5 29 174
5 Z 0.4×0.4 4 2.9 29 336.4
2--4 Z 0.4×0.4 4 2.8 29 324.8
底层 Z 0.4×0.4 4 3.1 29 359.6
注:1)表中g表示单位长度构件重力荷载;n为构件数量。
2)梁长度取净长;柱长度取层高。
(二)墙体参数计算
外墙为300mm厚的加气混凝土砌块,外墙面贴瓷砖(0.5kN/㎡),内墙面为厚20mm厚的抹灰,则外墙单位面积重力荷载为:0.5+5.7×0.3+17×0.02=2.55 kN/㎡
内墙为200mm厚的加气混凝土砌块,两侧均为20mm抹灰,则内墙单位面积重力荷载为:5.7×0.2+2×17×0.02=1.82kN/㎡
隔墙为100mm预制钢筋混凝土板墙,则单位隔墙面重力荷载为:0.1×25=2.5 kN/㎡
女儿墙为60mm预制钢筋混凝土板墙,则单位墙面重力荷载为:0.