kr .
(27)
U ⎛ s2 2
⎞⎟⎛ s ⎞⎟
⎜⎜ + r s +1⎟⎟⎜⎜
+1⎟⎟
G = V2 s C .
(25)
⎜⎝ 2
⎠⎟⎝⎜ ⎠⎟
2 + ip2
e
r2 r 2 r1
As shown in Table 3, the main parameters set in simulation are computed from design and selection of components, as well as load simulation. The equilibrium solutions and state parameters are changed while the piston pushes forward and accumulator discharges. Besides, the range and variation of pressure and flow rate are large in WAIM process. The viscosity of polymer melt is the main factor of load characteristic, and if we ignore the melt elasticity, the cut-off frequency of the load transfer function
Fig. 7. Open-loop control structure of pressure control system
For the reason of applications of the accumulator and differential pressure control, the system is uncontrollable
can be written as
L
B′
= L = .
mL mL
(28)
with derivative elements. As a result, the steady-state error of the load pressure will be infinite. Due to the static characteristic of force balance in the pressure cylinder, the model based feedback of the accumulator pressure for the differential pressure control is defined as
The visco-damping coefficient BL and cut-off frequency ωL increase following the increase of melt viscosity. The natural frequency of the accumulator is defined as
u′ = kfa pA A1 −uA3 ,
A2
(26)
a = =
, (29)
where kfa is the gain of the pressure transducer. In order to control the load pressure consistently with input, we should make pB response following the decrease of the accumulator pressure pA. Therefore, the pressure of accumulator pA is fed back to correct the input value of the proportional pressure relief valve. The pressure pB at inlet of the relief valve is regulated according to Eq. (26). By the model-based feedback, the system is transformed to a type 0 system. The structure of pressure control is improved and this simple controller is reliable, however, without any other compensation and load pressure feedback, a large
and ωL>ωa>250 rad/s, which is much higher than the
proportional relief valve. Therefore, the disturbance of parameter variation and deviations imported by linearization is negligible at low frequency.
Based on the model-based feedback of the accumulator pressure, the integral compensation is introduced to closed-loop control of the load pressure, as shown in Fig. 8. A series of Bode diagrams with different gains of integral part and non-integral compensation are shown in Fig. 9.
The magnitude of open loop is raised up with the increase of the integral gain, so the steady-state error will be reduced by closed-loop control. However, the system
·424·
ZHOU Hua, et al: Water-Assisted Injection Molding System Based on Water Hydraulic 水辅助注塑系统英文文献和中文翻译(8):http://www.youerw.com/fanyi/lunwen_79660.html