摘 要:锅炉是一种使用广泛,但具有危险性的工业设备。为了加强锅炉运行的安全性,在实际中必须严格地控制炉膛内的水位,温度和蒸汽压力,实时对这三个参数进行检测。本文所设计的锅炉报警控制系统采用AT89C2051作为处理器,通过DS18B20温度传感器和两个PT112传感器对相关信息进行采集,并且采用ISD1420语音芯片作为音频合成器。该锅炉报警控制系统可以有效提醒,及时发现锅炉问题。系统结构简单,功能易扩展,稳定性强。73175
Abstract:Boiler is a kind of industrial equipment, which is used widely。 In order to strengthen the safety of boiler operation, the water level, temperature and steam pressure in the furnace must be strictly controlled, and the three parameters must be measured in real time。 In this paper, AT89C2051 is used as a processor of the boiler alarm control system, DS18B20 and two PT112 is used to collect the relevant information in real time。 ISD1420 voice chip is used as audio synthesizer。 The boiler alarm control system can effectively remind, and find the problem of the boiler in time。 The system structure is simple, trivially expand, and high stability。
Keywords: boiler, MCU, sensor, alarm
目 录
1 绪论 4
1。1 研究背景及意义 4
1。2 国内外研究状况 5
1。3 发展前景 5
2 总体方案设计 6
2。1 方案设计 6
2。2 传感器的选择 6
2。3 AT89C2051单片机 9
2。4 A/D转换器 11
2。5 语音芯片 12
2。6 显示器的选择 14
3 系统硬件设计 15
3。1 CPU模块 15
3。2 报警模块 17
3。3信息采集模块 19
3。4电源模块 20
4 系统软件设计 20
4。1 主程序 20
4。2 DS18B20程序设计 21
4。3 放音子程序 22
4。4 录音子程序 23
5 系统仿真 24
结论 27
参考文献 28
致谢 29
附录 30
1 绪论
1。1 研究背景及意义
锅炉的作用是利用燃料燃烧所释放的热能将水加热产生水蒸气,水蒸气直接供给工业生产中所需的热能。它是由本体、附件仪表及附属设备组成。本体包括“锅”和“炉”两部分。“锅”是锅炉容纳蒸汽的受压部件。“炉”是燃烧设备,它使燃料进行燃烧产生灼热烟气,烟气经过炉膛和各段烟道向锅炉受热面放热,最后从锅炉尾部进入烟囱排出[1]。论文网