摘 要:无畸变目镜是用来观察前方光学系统所成图像的目视光学器件,是望远镜、显微 镜等重要的组成部分。本设计所使用的无畸变目镜为 4 片 2 组结构,使其能在视场角为 30° 的情况下,有一个良好的测量结果。该设计由专利资料中选用无畸变目镜的参数,基于 ZemaxTM 软件在初始结构上进行优化设计的。优化设计后的镜片色差变小,焦距变短,更适 用于测量用。72647
毕业论文关键词:无畸变目镜,ZemaxTM,优化,
Abstract:Orthoscopic eyepiece is the visual optics to observe the image of the front optical system and it is an important part of the telescope and microscope。 The eyepiece is made up of 4 pieces of lens and 。it has a good result of measurement in the field of view angle of 30°。 。The orthoscopic eyepiece parameters have been choosed from the patent information。And it has been optimized automatically through ZemaxTM。 After the sysytem has been optimiezed, the chromatic aberration of orthoscopic eyepiece and the length have been smaller。 Besides,it is much more suitable to measurement。
Keyword:orthoscopic eyepiece, ZemaxTM , optimize,
目录
1 绪论 3
1。1 无畸变目镜介绍 3
1。2 ZemaxTM 简介 3
2 目镜的结构分类及方案选择 4
2。1 按构造形式分类 4
2。2 按种类结构分类 5
2。3 无畸变目镜设计方案 6
3 无畸变目镜光学系统初始设计 6
3。1 目镜设计参数及镜片选择 6
3。2 光瞳直径、视场角度、主要波长的设定 7
3。3 2D 草图分析 8
3。4 光学传递函数(MTF)分析 9
3。5 点列图(Spot diagram)分析 9
3。6 目镜的光线像差(RayAberration)分析 10
3。7 轴外细光束像差曲线(fcd)分析 10
4 无畸变目镜的优化 11
4。1 优化函数的选择 11
4。2 2D 草图分析 12
4。3 光学传递函数(MTF)分析 12
4。4 点列图(Spot diagram)分析 13
4。5 目镜的光线像差(RayAberration)分析 13
4。6 轴外细光束像差曲线(fcd)分析 14
4。7 设计结果 14
总结 16
参考文献 17
致谢 18
1 绪论
随着科学技术的不断发展,光学仪器已经普遍应用在社会的各个领域。光学仪器的 核心部分是光学系统,光学系统成像质量的好坏决定着光学仪器整体的质量的好坏,一个 高质量的成像光学系统是要靠好的光学设计去完成。因此说,光学设计是实现各种光学仪 器的基础。本次设计就是采用了 ZEMAX 软件进行了对无畸变目镜的研究与设计,最终得到 符合设计要求的结果。
1。1 无畸变目镜介绍论文网
无畸变目镜已经成为业天文爱好者特别喜爱的目镜。目镜为 4 片 2 组结构,包括一个 Zemax30°视场角测量用无畸变目镜设计:http://www.youerw.com/wuli/lunwen_82673.html