[20] C.K. Cheung, R.J. Fuller, M.B. Luther, Energy efficient envelope design for high
rise apartments, Energy and Buildings 37 (2005) 37–48.
[21] H. Taha, H. Akbari, A. Rosenfeld, J. Huang, Residential cooling loads and the
urban heat island—the effects of albedo, Building and Environment 23 (1988)
271–283.
[22] R.W. Anderson, Radiation control coatings: an underutilized energy conserva-
tion technology for buildings, ASHRAE Transactions 95 (1989) 682–685.
[23] S. Konopacki, H. Akbari,M. Pomerantz, S. Gabersek, L. Gartland, Cooling energy
savings potential of light-colored roofs for residential and commercial build-
ings in 11 US metropolitan areas, Report No. LBNL-39433, Lawrence Berkeley
National Laboratory Berkeley, CA, 1997.
[24] A. Shariah, B. Shalabi, A. Rousan, B. Tashtoush, Effects of absorptance of external
surfaces on heating and cooling loads of residential buildings in Jordan, Energy
Conversion and Management 39 (1998) 273–284.
[25] X.X. Wang, C. Kendrick, R. Ogden, J. Maxted, Dynamic thermal simulation of
a retail shed with solar reflective coatings, Applied Thermal Engineering 28
(2008) 1066–1073.
[26] S. Konopacki, H. Akbari, Simulated impact of roof surface solar absorptance,
attic, and duct insulation on cooling and heating energy use in single-family
newresidential buildings, ReportNo. LBNL-41834, Lawrence BerkeleyNational
Laboratory Berkeley, CA, 1998.
[27] H. Akbari, S. Konopacki, C. Eley, B.Wilcox,M.V. Greem, D.S. Parker, Calculations
for reflective roofs insupport of Standard90.1,ASHRAE Transactions 104 (1998)
984–995.
[28] L. Gartland, S. Konopacki, H. Akbari, Modeling the effects of reflective roofing,
in: Proceedings of ACEEE 1996 Summer Study on Energy Efficiency in Building,
vol. 4, 1996, pp. 117–124.
[29] M.F. Tang, Y. Zhou, Applicability of exterior walls reflective thermal insulation
to energy efficient buildings in hot summer and cold winter zone, Journal of
HVAC&R 38 (2008) 41–44.
[30] H. Akbari, R. Levinson, Evolution of Cool-Roof Standards in the US, Advances in
Building Energy Research 2 (2008) 1–32.
[31] American Society of Heating, Refrigerating, and Air-Conditioning Engineers,
Inc. ANSI/ASHRAE/IESNA Standard 90.1: Energy Standard for Buildings Except
Low-rise Residential Buildings, Atlanta, 2007.
[32] American Society of Heating, Refrigerating, and Air-Conditioning Engineers,
Inc. ANSI/ASHRAE/IESNA Standard 90.2: Energy-Efficient Design of Low-rise
Residential Buildings, Atlanta, 2007.
[33] American Society ofHeating, Refrigeration andAir-Conditioning Engineers Inc.,
ASHRAE Handbook-Fundamentals, Atlanta, 2009.
where Tr is mean radiant temperature, K; TN is the surface tem-
perature of surface N,K; Fp−N is the angle factor between a person
and surface N. Mean radiant temperatures were calculated for a
standing person (height: 1.7m) in the middle of the room using
the measured surface temperatures and the respective angle fac-
tors [33], as shown in Fig. 8. Average reductions in calculatedmean
radiant temperature are 1.82 ◦C and 1.87 ◦C in summer and winter.
Themaximumreductions are 3.7 ◦C and 3.3 ◦C respectively, appear-
ing at 12:30 in summer and 11:50 in winter. Fig. 9 illustrates the
vertical air temperature distribution at these two peak times. Ther-
mal stratification naturally occurs in both BuildingsAand C, and the
difference in temperatures along the height of the (identical) rooms
is significant. At 1.7mfromthe floor (occupant height), the temper-
ature in Building A is 3 ◦C higher than the temperature in Building
C in the summer (similarly in winter).建筑物表面温度,室内反射涂层的影响,环境和能源消耗的实验研究 室内环境和反射涂层对建筑能耗影响英文文献和翻译(8):http://www.youerw.com/fanyi/lunwen_1963.html