21. Doukas D, Michelinakis G, Smith PW, Barclay CW (2008) The influence of interimplant distance and attachment type on the retention characteristics of mandibular overdentures on 2 implants: 6-month fatigueretention values. Introsthodont 21(2):152-154
22. Gulizio MP, Agar JR, Kelly JR (2005) Taylor TD effect of implant angulation upon retention of overdenture attachments. J Prosthodont 14(1):3-11
23. Michelinakis G, Barclay CW, Smith PW (2006) The influence of interimplant distance and attachment type on the retention characteristics of mandibular overdentures on 2 implants: initial retention values. Int J Prosthodont 19(5):507-512
24. Leung T, Preiskel HW (1991) Retention profiles of stud-type precision attachments. Int J Prosthodont 4(2):175-179
25. Haraldson T, Jemt T, Stalbald P, Lekholm U (1988) Functions in subjects with overdentures supported by osseointegrated implants. Scand J Dent Res 96:235-242
26. Brocher L, Reichart P (1983) Three dimensional stress distribu-tion around a dental implant at different stages of interface development. J Dent Res 62(2):155-159
27. Chen C, Brudvik JS, Lloyd A, Jeffrey M, Rubenstein E, Chitswe K, Ariel J (2011) Raigrodski freedom of rotation of selected overdenture attachments: An in vitro study. J Prosthet Dent 106(2): 78-86
28. Meijer HJA, Kuiper JH, Starmans FJM, Bosman FJM (1992) Stress distribution around dental implants: influence of super-structure, length of implant and height of mandible. J Prosthet Dent 68:96-102
29. Maeda Y, Horisaka M, Yagi K (2008) Biomechanical rationale for a single implant-retained mandibular overdenture: an in vitro study. Clin Oral Impl Res 19(3):271-275
30. Burns DR, John UW, Ronald EK Jr, Beck DA (1995) Prospective clinical evaluation of mandibular implant overdenture: Part I-retention stability and tissue response. J Prosthet Dent 73: 354-363
31. Chan MFWY, Johnson C, Howell RA, Cowood JI (1995) Pros-thetic management of the atrophic mandible using endosseous implants and overdentures. Br Dent J 179:329-337
32. Zmudzki J, Chladek W, Krukowska J (2009) Attachments of implant retained tissue supported denture under biting forces. Arch Comput Mater Sci Surf Eng 1(1):13-20
33. Bathe K-J (2002) Finite element procedure, 6th edn. Prentice- Hall of India Pvt Ltd
摘要:当今,种植磁性覆盖义齿已广泛应用,是无牙颌患者的有效的治疗方法。种植覆盖义齿的普及创造了检查各种连接系统被使用的必要性,分配到牙槽骨的应力。因此,三文有限元进行分析在下颌骨应力分布与种植体支持的有球帽性和不同直径的磁性附着体覆盖义齿。一段下颌骨前牙区种植覆盖义齿进行。四种不同的模型生成具有球帽型和磁性附着体。从水平、垂直和倾斜方向分别施加10、35和70N的力,并研究了应力分布。得出的结论是压力最大浓度出现在皮质骨嵴可减少使用较小尺寸的高度,种植覆盖义齿。论文网
关键词 种植覆盖义齿 有限元分析 建模 下颌
随着人类寿命的延长,很多人活得比他们的牙齿。对治疗老年患者,特别是那些残疾人,可能是一项艰巨的挑战。处理此类案件的最终目标是使患者恢复到一定水平的满意的美学,语音的生理功能、吞咽和咀嚼功能。完整的下颌义齿功能的问题,造成问题的最主要的原因是因为保留的很少。同时骨吸收明显的下颌骨比上颌骨牙多。由于全口义齿依靠残余牙槽嵴的支持和保留,这是最受影响的下颌义齿的自然过程。覆盖义齿可以作为一种治疗方式损害完全无牙颌患者尤其是下颌弓。整口覆盖义齿是通过种植体支持固位钉或磁性附着体是类似于天然牙的牙。植入物的最小数量的使用是足够的修复支持和保留也是经济效益的患者。
- 上一篇:注射成型微流控芯片英文文献和中文翻译
- 下一篇:计算机数字控制(CNC)英文文献和中文翻译
-
-
-
-
浅析中国古代宗法制度
上市公司股权结构对经营绩效的影响研究
高警觉工作人群的元情绪...
巴金《激流三部曲》高觉新的悲剧命运
中国传统元素在游戏角色...
江苏省某高中学生体质现状的调查研究
现代简约美式风格在室内家装中的运用
C++最短路径算法研究和程序设计
NFC协议物理层的软件实现+文献综述
g-C3N4光催化剂的制备和光催化性能研究