摘要无功功率是影响电压质量的一个重要因素,电压质量与无功是密不可分的,可以说,电压问题本质上就是无功问题,解决好无功补偿问题,具有十分重要的意义。
本文主要阐述了一种TCR-TSC型无功补偿装置(SVC)设计,在对TSC和TCR两种无功补偿装置的分析理解的基础上,对其使用性能进行分析,将二者设计成一个整体,让二者相互配合工作。通过对系统级模型进行理论分析,利用了对于线路上功率因数的控制和反馈,采用MATLAB对模拟系统进行了仿真,仿真结果表明了该设计方法的正确性和有效性。9914
关键词:TCR;TSC;无功补偿;SVC
毕业设计说明书(论文)外文摘要
Title Research on TCR-TSC Static Var Compensator(SVC) Based on MATLAB
Abstract
Reactive power is one of the important factors to influence the quality of voltage , voltage quality and Reactive is inseparable, Voltage problem is essentially a reactive problem. It is of vital significance to solve the problem of reactive compensation.
A TCR—TSC static var compensator(SVC)is designed in this paper.TSC and TCR are two kinds of reactive power compensation device,on the the basis of analysising and understanding them It is analyzed that the SVC system-level model to Use of on-line power factor control and feedback. Then the model system is simulated by using MATLAB.Simulation results show the correctness and effectiveness of the design.
Keywords: TCR ;TSC; reactive power compensation; SVC
目 次
1 引言 1
1.1无功补偿概述 1
1.2 无功补偿的意义和经济效益分析 1
1.3 无功补偿的降损节能应用 3
2 无功补偿的基本知识 7
2.1 功率因数 7
2.2 无功补偿的基本原理 7
3 仿真原理 12
3.1 晶闸管投切电容器12
3.2 晶闸管控制电抗器13
3.3 TSC+TCR14
4 电路设计和仿真析15
4.1 单独TSC仿真电路15
4.2 FC+TCR构成的无功发生器17
4.3 TSC+TCR组合无功发生器20
结论 31
致谢 32
参考文献33
1 引言
1.1.无功补偿概述
电力系统运行的经济性和电能质量与无功功率有重大的关系。无功功率是电力系统一种不可缺少的功率。大量的感性负荷和电网中的无功功率损耗;要求系统提供足够的无功功率,否则电网电压将下降,电能质量得不到保证。同时,无功功率的不合理分配,也将造成线损增加,降低电力系统运行的经济性[1]。
电网中无功不平衡主要有两方面的原因:一方面是输送部门传送的三相电的质量不高,一方面是用户的电气性能不够好。这两方面的原因综合起来导致了无功的大量存在、在电力系统中,电压和频率是衡量电能质量的两个最重要的指标。为确保电力系统的正常运行,供电电压和频率必须稳定在一定的范围内。频率的控制与有功功率的控制密切相关,而电压控制的重要方法之一就是对电力系统的无功功率进行控制。
现如今大部分用电设备为感性负载,自然功率因素较低,用电设备在消耗有功功率的同时,还需无功功率由电源送往负荷。功率因素是供用电系统的一项重要技术指标,通过合理采用无功补偿技术。可以减少无功功率在电网中的流动。