holes were located with same intervals in a plain met at right angles. The diameter of a hole, length to diameter ratio ([n/dn) of the nozzle and nozzle hole total area were 0.32 mm, 2.81 and 0.412 mm


holes  were  located  with  same  intervals  in  a  plain
met  at  right  angles.  The  diameter  of a  hole,  length
to  diameter  ratio  ([n/dn)  of the  nozzle  and  nozzle
hole  total  area  were  0.32 mm,  2.81  and  0.412  mm  2,
respectively.  The  diameter  and  [n/dn  of the  single
-hole  were  0.32 mm  and  2.81,  which  are  the  same
as  those  of  the  multi-hole  nozzle.  The  rotating
speed  of  the  pump  in  this  experiment  was  set  up
to  500  rpm  with  constant  total  injection  quantity
of  30 mm3/st.  The  injection  quantity  of  a  tested
hole  was  7.31  mm3/st,  and  that  of  the  single-hole
nozzle  was  the  same.  The  injection  duration  was
1.l.and  0.8 ms  for  the  5-hole  and  the  single-hole
nozzle,  respectively.
2.3  PDPA  system
The  droplet  size measurements  of the  fuel  spray
were  carried  out  by  a  2-dimensional  PDPA  (Dan-
tec  Co.)  system.  The  PDPA  system  consists  of  a
transmitter  optics  with  a  750 mW  air  cooled  Ar-
ion  laser  as  a  light  source,  receiver  optics  as  a
scattered  light  collection  system,  a  signal  pro-
cessing  electronics  (Dantec  Co.,  58N50),  a  three
I
III  Tradm,  g  e~'k:je
Outer
regqon
',.,  "\  /
a,r  ~,  '\..
/
/  ¢
",...  "..,..,~.  J  ./
$'fl
Fig.  3
~1 Central  part
MnXd~:.g
flow  region
~-  I.  Lead~n9  edge
Illustration  of  typical  structure  of  spray
formed  by  diesel  nozzle  and  definitions  of
coordinate  system  in  spray  flow  field
dimensional  traverse  and  data  acquisition  system
including  a  computer.  Two  laser  beams,  repres-
enting  the  wavelengths  of  514.5  (green)  and  488
(blue)  nm,  from  transmitting  optics  cross  at  one
point  and  form  a  measurement  volume.  Receiving
optics  detects  the  scattered  lights,  which  is  pro-
duced  when  droplets  pass  through  the
measurement  volume,  and  then  transmits  them  to
the  signal  processor.  Therefore,  the  droplet  size  is
measured  by  the  frequency  and  relative  phase
difference  of  the  Doppler  signal.
The  measurement  of  the  droplet  size  was  con-
ducted  in  the  two  dimensions  at  axis  because  the
sprays  would  be  considered  as  an  axi-symmetric
structure  in  the  spray  flow  field.  Figure  3  shows
the  schematic  diagram  of  the  typical  structure  of 柴油喷嘴雾化英文文献和翻译(4):http://www.youerw.com/fanyi/lunwen_1165.html