摘要: 本设计为南京市某度假村地源热泵中央空调系统。与传统空调相比,在节能方面有很大的优势。本设计内容包括:空调冷负荷的计算;空调系统的划分与系统方案的确定;冷源的选择;空调末端处理设备的选型;风系统的设计与计算;室内送风方式与气流组织形式的选定;水系统的设计、布置与水力计算;地埋管换热器的选型;风管系统与水管系统保温层的设计;消声防振设计等内容。在节约能源和舒服的要求下,采取风机盘管加新风系统这套组合。22856
关键词: 度假村;地源热泵;传统空调系统;地埋管换热器;地源热泵中央空调系统
Ground-source Heat Pump Central Air Conditioning System Design for the Resort in Nanjing City
Abstract: The graduation project designs a ground-source heat pump central air conditioning system design for the resort in Nanjing city. Compared with traditional air conditioning system, it has a great advantage in energy conservation. It contains: cooling load calculation; the estimation of system zoning; the selection of refrigeration units; the selection of air conditioning equipment; the design of air duct system and calculation; the estimation of air distribution method and the selection of relevant equipment; the selection of ground heat exchanger; the design of water system and its resistance analysis; the insulation of air duct plant and chilled water pipes; noise and vibration control; etc. According to some correlation standard, allow for energy safe and indoor comfort, the air condition system of the design is Fan coil units (FCUs)--fresh air system.
Keywords: The resort; Ground source heat pump; traditional air conditioning system; Ground heat exchanger; Ground source heat pump air conditioning system
目录
1 绪论 1
1.1 课题背景和意义 1
1.2 国内外研究现状和水平 1
1.3 发展趋势 2
1.4 地源热泵优点 2
1.5 地源热泵在中国推广的问题 3
2 工况概况及设计依据 5
2.1 设计依据 5
2.2 建筑平面图和剖面图 5
2.3 国家主要规范和行业标准 5
2.4 工程概况 5
2.5 气象参数和地质参数 5
2.6 地源热泵系统简介 6
2.7 初步方案 6
3 负荷计算 8
3.1 夏季空调冷负荷计算 8
3.1.1 围护结构冷负荷 8
3.1.2 室内热源散热形成的冷负荷 9
3.2 冬季热负荷的计算 11
3.2.1 围护结构基本耗热量 11
3.2.2 围护结构的修正耗热量 12
3.3 湿负荷计算 12
3.4 负荷计算数据汇总 13
4 新风负荷的计算 15
4.1 新风量的确定 15
4.2 夏季空调新风冷负荷的计算 15
4.3 新风量汇总及新风负荷 15
5 空气处理设备的选型 17
5.1 风机盘管的选型 17
5.1.1 送风量的计算 17 南京某度假村地源热泵中央空调系统的设计+CAD图纸:http://www.youerw.com/gongcheng/lunwen_15670.html