Speed Control of DC Motor Abstract Conditioning system is characterized in that output power to maintain stability. Different speed control system can use a different brake system, high starting and braking torque, quick response and quick adjustment range of degree requirements of DC drive system, the use of the electric braking mode. Depends on the speed control of DC motor armature voltage and flux. To zero speed, or U = 0 or Φ = ∞. The latter is impossible, it only changes through the armature voltage to reduce speed. To speed to a higher value can increase or decrease the U Φ.70360
Keyword:DC Speed Feedback Brake
Regulator Systems
A regulator system is one which normally provides output power in its steady-state operation.
For example, a motor speed regulator maintains the motor speed at a constant value despite variations in load torque. Even if the load torque is removed, the motor must provide sufficient torque to overcome the viscous friction effect of the bearings. Other forms of regulator also provide output power; A temperature regulator must maintain the temperature of, say, an oven constant despite the heat loss in the oven. A voltage regulator must also maintain the output voltage constant despite variation in the load current. For any system to provide an output, e.g., speed, temperature, voltage, etc., an error signal must exist under steady-state conditions.
Electrical Braking
In many speed control systems, e.g., rolling mills, mine winders, etc., the load has to be frequently brought to a standstill and reversed. The rate at which the speed reduces following a reduced speed demand is dependent on the stored energy and the braking system used. A small speed control system (sometimes known as a velodyne) can employ mechanical braking, but this is not feasible with large speed controllers since it is difficult and costly to remove the heat generated.
The various methods of electrical braking available are:
(1) Regenerative braking.
(2) Eddy current braking.
(3) Dynamic braking.
(4) Reverse current braking(plugging)
Regenerative braking is the best method, though not necessarily the most economic. The stored energy in the load is converted into electrical energy by the work motor (acting temporarily as a generator) and is returned to the power supply system. The supply system thus acts as a”sink”into which the unwanted energy is delivered. Providing the supply system has adequate capacity, the consequent rise in terminal voltage will be small during the short periods of regeneration. In the Ward-Leonard method of speed control of DC motors, regenerative braking is inherent, but thyristor drives have to be arranged to invert to regenerate. Induction motor drives can regenerate if the rotor shaft is driven faster than speed of the rotating field. The advent of low-cost variable-frequency supplies from thyristor inverters have brought about considerable changes in the use of induction motors in variable speed drives.
Eddy current braking can be applied to any machine, simply by mounting a copper or aluminum disc on the shaft and rotating it in a magnetic field. The problem of removing the heat generated is severe in large system as the temperature of the shaft, bearings, and motor will be raised if prolonged braking is applied.
In dynamic braking, the stored energy is dissipated in a resistor in the circuit. When applied to small DC machines, the armature supply is disconnected and a resistor is connected across the armature (usually by a relay, contactor, or thyristor).The field voltage is maintained, and braking is applied down to the lowest speed. Induction motors require a somewhat more complex arrangement, the stator windings being disconnected from the AC supply and reconnected to a DC supply. The electrical energy generated is then dissipated in the rotor circuit. Dynamic braking is applied to many large AC hoist systems where the braking duty is both severe and prolonged.