Floor No. 4 Tower No. 1
Xstif= 16.9740(m) Ystif= 20.2048(m) Alf = 0.0000(Degree)
Xmass= 14.8472(m) Ymass= 20.4008(m) Gmass(活荷折减)= 431.3127( 423.1382)(t)
Eex = 0.0820 Eey = 0.0081
Ratx = 0.3563 Raty = 0.3563
Ratx1= 1.0000 Raty1= 1.0000
薄弱层地震剪力放大系数= 1.00
RJX1 = 1.6531E+06(kN/m) RJY1 = 1.6531E+06(kN/m) RJZ1 = 0.0000E+00(kN/m)
RJX3 = 1.9454E+05(kN/m) RJY3 = 2.6278E+05(kN/m) RJZ3 = 0.0000E+00(kN/m)
---------------------------------------------------------------------------
X方向最小刚度比: 1.0000(第 4层第 1塔)
Y方向最小刚度比: 1.0000(第 4层第 1塔)
============================================================================
结构整体抗倾覆验算结果
============================================================================
抗倾覆力矩Mr 倾覆力矩Mov 比值Mr/Mov 零应力区(%)
X风荷载 2019685.4 6884.3 293.37 0.00
Y风荷载 974702.4 14755.7 66.06 0.00
X 地 震 1937812.8 66935.6 28.95 0.00
Y 地 震 935190.6 67306.5 13.89 0.00
============================================================================
结构舒适性验算结果(仅当满足规范适用条件时结果有效)
============================================================================
按高钢规计算X向顺风向顶点最大加速度(m/s2) = 0.031
按高钢规计算X向横风向顶点最大加速度(m/s2) = 0.001
按荷载规范计算X向顺风向顶点最大加速度(m/s2) = 0.028
按荷载规范计算X向横风向顶点最大加速度(m/s2) = 0.002
按高钢规计算Y向顺风向顶点最大加速度(m/s2) = 0.059
按高钢规计算Y向横风向顶点最大加速度(m/s2) = 0.002
按荷载规范计算Y向顺风向顶点最大加速度(m/s2) = 0.051
按荷载规范计算Y向横风向顶点最大加速度(m/s2) = 0.007
============================================================================
结构整体稳定验算结果
============================================================================
层号 X向刚度 Y向刚度 层高 上部重量 X刚重比 Y刚重比