摘要 这个设计是关于上海市华贸中心-E区空调系统的,需要为它设计一个恰当的空调系统,为顾客以及室内的工作人员等提供一个健康舒适的环境。
此次设计依照该建筑各部分的结构特点及它的用途,在仔细考量室内环境的舒适度,运行管理上的方便和节能等各个方面的大基础上,再来根据有关规范考虑有关节能和舒适性的要求,对一层等一些较大的空间选用全空气系统,而对办公室等小空间则选用风机盘管加新风系统。这样就能够满足不同功能房间使用时间段人员活动情况的不同要求,控制方便,布置灵活。61769
毕业论文关键词 综合楼;全空气系统;风机盘管—新风系统;节能
ShangHai HuaMao Trade Center- Air Conditioning System Engineering Of E Area
Abstract This design for the Shanghai XX building central air-conditioning system, draws up for it design reasonable central air-conditioning system, for the office work personnel, the visitor and so on provides a comfortable health the environment.
This design acts according to this building various part of unique feature and the use, in full consideration indoor environment comfortableness, the movement management convenience and the energy conservation and so on in various aspects foundation, and based on the related standard consideration energy conservation and the comfortable request, and so on the big space uses the entire air system to a building, but and so on the small space uses the air blower serpentined to the guest room to add the new atmosphere system.This may satisfy the different function room period of revolution section personnel to move the situation the different request, the arrangement is nimble, the control is convenient.
Key Word The guesthouse; entire air system; Fan coil units (FCUs) -- new atmosphere system ;Conserves energy
1 工程概况及设计内容 1
1.1 工程概况 1
1.2 土建资料 1
1.3 设计内容及依据 4
1.3.1 设计内容 4
1.3.2 设计依据 5
1.3.3 设计参数 5
2 空调系统的负荷计算 6
2.1 二十三层的负荷计算 10
2.1.1 办公室负荷计算 12
2.1.2 二十三至二十四层各房间冷负荷汇总 20
3 空气处理过程设计以及设备选型 21
3.1 标准房间1(FCU+新风)空气处理过程和设备选型 21
3.1.1 空调方式设计 21
3.1.2 送风状态及送风量确定 21
3.1.3 设备选择 22
3.1.4 FCU+新风系统的新风机组的选择 23
3.2 其它各层各房间空调方式、设备选型汇总 24
3.2.1 二十三层空调房间的空调方式、设备选择汇总 24
4 空调房间气流组织设计 25
4.1 标准层空调房间气流组织设计 25
4.1.1 二十三层办公室区01气流组织设计 25
4.2 风系统的水力计算