摘要:在电站锅炉中 ,在炉膛内烟气的热量传递给水之后,水变为蒸汽,过热器的作用为将饱和蒸汽加热到具有一定温度的过热蒸汽,以提高电站效率。对流过热器、屏式过热器和辐射式过热器三部分组成了600MW汽轮机发电机组过热器系统,最终目的是加热蒸汽至温度605℃。针对屏式过热器进行热力计算和结构设计,结构合理,热力性能良好,并绘制图纸。屏式过热器采用标准立式布置,多管圈结构;蛇形管采用12Cr2MoVB材质,总传热面积为3403m2。76183
毕业论文关键词: 过热系统;屏式过热器;结构设计;热力计算
Design of Superheater System for 600MW Ultra Supercritical Boiler
Abstract: In the power plant boiler, the heat in the furnace after the heat transfer to the water, the water into steam, the role of the superheater to heat the saturated steam to a certain temperature of the superheated steam to improve power efficiency。 600MW steam turbine generator superheater system consists of convection superheater, screen superheater and radiation superheater composed of three parts, and finally heat the steam to the temperature of 605 ℃。 For the superheater thermal calculation and structural design, reasonable structure, good thermal performance, and drawing drawings。 The superheater is made of standard vertical arrangement and multi-tube structure。 Snake tube adopts 12Cr2MoVB material。 The total heat transfer area is 3403m2。
Keywords: superheating system; Screen superheater; Structural Design; Thermodynamic Calculation
目录
摘要 i
Abstract i
目录 ii
1 绪论 1
1。1 本课题的目的和意义以及国内外研究现状、水平和发展趋势 1
1。2 火电厂的工作原理和设备 3
1。3 汽水系统 3
1。4 过热系统 4
1。5 屏式过热器 5
2 屏式过热器热力计算 7
2。1 半辐射受热面传热系数的计算 7
2。1。1 屏式受热面传热系数计算 7
2。1。2 屏式受热面烟气放热系数计算 8
2。1。3 屏式受热面烟气对流放热系数计算 8
2。1。4 屏空间烟气辐射放热系数计算 9
2。2 半辐射受热面吸收的炉内直接辐射的计算 9
2。2。1 屏布置在炉膛出口烟窗时来自炉内的直接辐射计算 9
2。3 半辐射受热面工质侧和烟气侧热平衡方程 10
2。3。1 计算过程 11
2。3。2