摘要:电机最简单的起动方式就是采用直接起动,但是电机直接起动时,会使得电网电压产生较大的波动,影响电网上的其他用电设备的正常工作。电机在起动的一瞬间会产生较大的冲击电流,冲击电流中包含了正弦电流和谐波电流。本文针对传统的起动方法存在的大起动电流、小转矩问题提倡采用一种软起动方式—晶闸管调压软起动。通过一定频率和一定宽度的脉冲来触发晶闸管的导通从而达到无触点调压起动的目的,这样可以保证电流的连续性,使得电机不会产生过大的冲击电流,并且能够获得较为线性的起动转矩。5优尔2
毕业论文关键词:起动电流,起动转矩,软起动,晶闸管调压
Abstract: The simplest way of starting motor is the direct starting, but direct starting of motor, makes large power grid voltage fluctuations, affect the normal work of the other electrical equipment in the power grid. Motor will have a larger impact at the moment of starting current and impact current contains the harmonic current and harmonic current. Based on traditional method of starting the problems of large starting current, small torque advocates a way of soft start, thyristor regulating soft start. Through a certain frequency and a certain width of pulse to touch the hair crystal thyratron conduction so as to achieve the aim of non-contact voltage regulator starting, so that we can ensure the continuity of current, make the motor will not have too big impact current, and can obtain more linear starting torque.
Key words: starting current , starting torque, soft start ,thyristor voltage regulation
目录
1 前言 4
2 电机起动的现状 5
2.1 国内外电机起动技术现状和发展趋势 5
2.2 传统的异步电机的主要起动方法 6
3 新型起动--软起动 8
3.1.1 软起动器的保护功能 9
3.1.2 软起动的工作原理及应用 10
3.2 传统软起动与新型电子式软起动的比较 14
3.3 谐波的危害 15
3.4 谐波的去除方法 16
4 基于晶闸管的交流调压软起动 16
4.1 电机稳态数学模型 16
4.2 单相交流调压原理 17
4.3 三相交流调压原理 20
5 电机起动系统仿真 22
5.1 全压起动的仿真 22
5.2 晶闸管调压软起动的仿真 24
结论 26
参考文献 27
致谢 28
1 前言
电机在现代工农业生产和交通运输中具有举足轻重的地位,是重要的生产设备,但是目前用户关注的焦点正悄悄地转向于与电机配套的一些相关控制设备的性能。电机的起动、调速和制动都属于电机的控制范畴。异步电机之所以在电力拖动平台上能够得到广泛的应用是因为其结构简单、体积小、运行可靠、价格低廉、运行效率较高、维修方便、工作特性较好等优点。据最新数据反应,全国超过40%的发电量都是由电机消耗掉的。电机的起动过程是指当电机并入电网时,电机转速从静止加速到额定转速的过程。电机的起动转矩和起动电流是异步电机起动性能的两项重要标准。因此在电机的起动过程中,如何增大起动转矩,降低起动电流,是我们一直以来需要探讨的重要课题。