摘 要:本论文是拟对青海某某地20兆瓦并网光伏电站光伏场区内电气一次设计方案,主要包括光伏组件布置、主接线图设计、短路电流计算、电气设备的选型、防雷接地保护等设计,并通过此优化设计得出合理完整的电气一次设计方案。62789
本设计规划装机容量为50MW,分期建成,本期建设20MW,光伏场区内新建一座110kV升压站,最终经1回110kV架空线路并入电网侧330kV变电站110kV进线间隔,光伏场区发电系统主要包括光伏组件、逆变器、汇流箱、箱式升压变等设备及电缆组成,本文将从可靠性、经济性、安全性角度对该光伏电站进行设计。
毕业论文关键词:光伏电站,短路电流计算,优化设计
Abstract:This paper is proposed for 20 MW photovoltaic grid photovoltaic power station somewhere prefecture in QingHai area electrical design scheme at a time, Mainly includes the photovoltaic modules layout, main wiring diagram design, short-circuit current calculation, electrical equipment selection, design of lightning protection grounding protection, And through the optimized design reasonably come to the complete electrical design scheme at a time.
The design plan of the installed capacity of 50 MW, built in stages, with the current construction of 20 MW, Photovoltaic field area to build a new 110 KV booster station, Finally by 1 to 110 KV overhead line grid side 330 KV substation 110 KV line interval, Photovoltaic power generation in jobsite system mainly including pv modules, inverters, junction box, box-type booster equipment and cables.This article from the Angle of reliability, economy and safety of the photovoltaic power station design.
Keywords: photovoltaic power station,short circuit current calculation,optimization design
1 绪论 3
1.1 课题的研究背景及意义 3
1.2 项目意义 4
1.3 光伏发电在国内外的发展状况 5
2 接入电力系统方案 7
2.1 电力系统现状 7
2.2 接入系统方案 7
3 电气主接线 8
3.1 电气主接线设计要求 8
3.2 电气主接线常用形式及比较 8
3.3 本项目电气主接线图 10
4 电气设备选择 14
4.1 短路电流计算 14
4.2 主要电气设备选择 20
5 防雷、接地及过电压保护 24
5.1 直击雷保护的措施 24
5.2 接地要求 25
6 光伏阵列部分 26
6.1 光伏阵列基础计算 27
6.2 电气设备布置 29
结论 32
参考文献 33
致谢 34
附录A 35
附录B 36
附录C 37
1 绪论
目前,在世界能源结构领域中,人类依然主要依赖与化石能源,其中石油、天然气、煤炭的消费构成大约为41%、23%和27%。据各个国际统计,能源存储仅能供用于各国消费使用大约170年。具体来说,石油仅仅能使用大约40年,天然气仅仅能够使用大约60年,煤炭也仅能使用220年。由此可知,在人类开发利用能源现阶段中,以石油、天然气、煤炭等化石燃料能源为主的时间非常有限,因此新能源取代化石能源是历史的必然选择。从“十一五”规划中就明确鼓励新能源发电和节能项目的发展。在2012八月国家能源局制定的《可再生能源发展“1025”规划》正式颁布,明确指出: