According to the 《Code for design of automatic water spraying fire extinguishing system》 in the setting of fire danger rating for example, the design object is in danger grade I. The interior of the building is provided with a wet automatic sprinkler system, the design of water injection intensity is not less than 6L/ (m2 / min), the most unfavorable point in the area of the number of nozzles is 15. Automatic sprinkler system design flow is 28.84L/s, water pressure is 1.377MPa, the safety factor takes 1.10, the fire pump needs the head is 151.5mH2O. Centrifugal fire pump XBD16/40-150 two sets, one with a preparation, flow rate of 40L/s, head of 160mH2O, speed of 2900r/min, the power of 90kW, the efficiency of 78%. The effective volume of the fire pool should be 424.8m3, in the underground garage to set a 500m3 fire pool, indoor fire water are taken from the pool.

The building for the first level protection of the object, the entire building design centralized alarm control system. Each layer as a separate alarm area; the detection region is pided according to inpidual rooms, staircases, corridors, lobby were also pided into separate detection area. The detection range selection of smoke detectors, fire alarm system of indoor hydrant system, linkage control system, smoke control system, fire shutter and sound light alarm device of the automatic sprinkler, the control mode is pided into manual / automatic control / manual hard line direct control, ensure the reliable operation of the system equipment.

目录:

1 绪论 - 1 -

1.1 工程资料 - 1 -

1.1.1 建筑基本概况 - 1 -

1.1.2 消防设计任务 - 1 -

1.1.3 设计标准及规范 - 1 -

1.2 国内外综合商业体消防设计研究现状 - 2 -

1.2.1 国内消防安全现状 - 2 -

1.2.2 国外消防安全现状 - 2 -

1.2.3 酒店建筑火灾特点 - 3 -

1.2.4 酒店消防问题应对策略 - 4 -

1.3 设计内容 - 6 -

2 建筑总平面设计 - 7 -

2.1 建筑分类和耐火等级 - 7 -

2.2 防火间距 - 7 -

2.3 消防车道设计 - 7 -

3 建筑平面防火设计 - 9 -

3.1 防火分区划分 - 9 -

3.2 防烟分区的划分 - 9 -

4 安全疏散 - 11 -

4.1 疏散安全出口 - 11 -

4.2 疏散楼梯间 - 11 -

4.3 安全疏散距离 - 12 -

5 建筑灭火器配置 - 13 -

5.1 灭火器配置场所火灾种类及危险等级 - 13 -

5.1.1灭火器配置场所火灾种类 - 13 -

5.1.2 灭火器配置场所危险等级 - 13 -

5.2 灭火器最低配置基准 - 14 -

5.3 灭火器的保护距离 - 14 -

5.4 灭火器的配置计算 - 14 -

5.4.1 计算单元的需配最低灭火级别 - 14 -

5.4.2 确定该单元的灭火器设置点数与各点的位置

上一篇:18层剪力墙上海顾村1号楼建筑结构设计
下一篇:6层上海某综合楼中央空调系统设计+CAD图纸

试谈建筑消防给排水施工...

试析消防电气技术茬超高...

浅谈高层建筑给排水消防设计【2151字】

浅谈建筑电气消防安全管理工作【2406字】

浅谈建筑工程施工现场的...

浅析建筑消防电气的安装...

民用建筑消防给排水设计要点分析【2530字】

安康汉江网讯

网络语言“XX体”研究

张洁小说《无字》中的女性意识

新課改下小學语文洧效阅...

老年2型糖尿病患者运动疗...

麦秸秆还田和沼液灌溉对...

我国风险投资的发展现状问题及对策分析

LiMn1-xFexPO4正极材料合成及充放电性能研究

ASP.net+sqlserver企业设备管理系统设计与开发

互联网教育”变革路径研究进展【7972字】