摘要此毕业设计对无锡某综合楼进行整个的空调系统设计,其中包括空调冷热源设计,管路系统设计,末端空调系统设计,建筑防排烟设计。冷热源系统采用电动螺杆冷水机组和锅炉;管路设计为冬夏季共用的两管制竖直同程水平异程式系统;建筑中商场和多功能厅采用全空气系统,办公和酒店式公寓楼程则采用风机盘管+新风系统;防排烟设计为核心筒防排烟,对楼梯间和电梯前室采用加压送风系统。66184
毕业论文关键词 空调系统 冷热源 管路系统 建筑防排烟
毕业设计说明书(论文)外文摘要
Title Wuxi City, a complex building air conditioning engineering design
Abstract This graduation design a complex building in Wuxi for the entire air conditioning system design, including the design of air conditioning heat and cold sources, piping systems design, terminal air conditioning system design, architectural design of smoke. Heating and cooling systems using electric screw chillers and boilers; piping design for the winter and summer shared two different control levels of vertical programs with the way the system; building shopping centers and multifunctional hall with full air system, office and hotel-style apartment building process is used FCU + fresh air system; smoke tube design as the core of the stairwell and elevator room pressurized air supply system
Keywords Air-conditioning system Cold source Piping Systems Building exhaust
目 次
1 绪论 2
1.1 工程概况 2
1.2 设计依据 2
1.2.1 设计目的 3
1.2.2设计任务及要求 3
2 空调负荷计算 4
2.1 空调设计的原始气象参数 4
2.2 综合楼建筑的围护结构参数 4
2.3 空调负荷计算 5
2.3.1空调冷负荷 5
2.3.2空调热负荷 12
2.4 空调负荷计算结果分析 13
3 空调系统冷热源的设计 14
3.1 空调冷热源的分类 15
3.2 空调冷热源方案的确定 15
3.3 空调冷热源机房的设计 15
3.3.1 冷水机组的设计与选型 15
3.3.2 锅炉的设计与选型 16
3.3.3 板式换热器的设计与选型 16
4 空调方式的设计 17
4.1 建筑功能特点及典型空调方式 17
5 空气处理设备设计与选型 18
5.1 卧式组合式空调机组的设计选型 18
5.2 风机盘管机组的设计选型 21
6 空调风系统设计 23
6.1 风道设计 23
6.2 风管水力计算 23
6.3 风口与气流组织设计