RJX1 = 7.3543E+06(kN/m) RJY1 = 7.3543E+06(kN/m) RJZ1 = 0.0000E+00(kN/m)
RJX3 = 6.4066E+05(kN/m) RJY3 = 6.5551E+05(kN/m) RJZ3 = 0.0000E+00(kN/m)
---------------------------------------------------------------------------
Floor No. 7 Tower No. 1
Xstif= 51.优尔0(m) Ystif= 3.8341(m) Alf = 0.0000(Degree)
Xmass= 51.9306(m) Ymass= 3.5404(m) Gmass(活荷折减)= 105.5467( 97.9163)(t)
Eex = 0.0314 Eey = 0.0616
Ratx = 0.1460 Raty = 0.1460
Ratx1= 1.0000 Raty1= 1.0000
薄弱层地震剪力放大系数= 1.00
RJX1 = 1.0738E+06(kN/m) RJY1 = 1.0738E+06(kN/m) RJZ1 = 0.0000E+00(kN/m)
RJX3 = 1.0675E+05(kN/m) RJY3 = 1.0081E+05(kN/m) RJZ3 = 0.0000E+00(kN/m)
---------------------------------------------------------------------------
X方向最小刚度比: 1.0000(第 7层第 1塔)
Y方向最小刚度比: 1.0000(第 7层第 1塔)
============================================================================
结构整体抗倾覆验算结果
============================================================================
抗倾覆力矩Mr 倾覆力矩Mov 比值Mr/Mov 零应力区(%)
X风荷载 2648562.5 7181.2 368.82 0.00
Y风荷载 802049.4 21624.3 37.09 0.00
X 地 震 2580269.2 117404.4 21.98 0.00
Y 地 震 781368.6 108902.9 7.17 0.00
============================================================================
结构舒适性验算结果(仅当满足规范适用条件时结果有效)
============================================================================
按高钢规计算X向顺风向顶点最大加速度(m/s2) = 0.022
按高钢规计算X向横风向顶点最大加速度(m/s2) = 0.004
按荷载规范计算X向顺风向顶点最大加速度(m/s2) = 0.022
按荷载规范计算X向横风向顶点最大加速度(m/s2) = 0.003
按高钢规计算Y向顺风向顶点最大加速度(m/s2) = 0.067
按高钢规计算Y向横风向顶点最大加速度(m/s2) = 0.004
按荷载规范计算Y向顺风向顶点最大加速度(m/s2) = 0.069
按荷载规范计算Y向横风向顶点最大加速度(m/s2) = 0.051
============================================================================