Keywords:Building thermal design Air-conditioning Photovoltaic Off-grid Residential buildings should be places in which their occupants feel comfortable and content。 In an energy conscious world the challenge of offering improved indoor comfort is contrast with the desire to minimise grid energy consumption (both from an efficient distribution perspective and to minimise fossil fuel consumption) as well as the associated cost。 Occupant behaviour is one of the key drivers of energy consumption, and in particular peak energy consumption, which is largely the result of air- conditioner usage。 Selecting the most cost effective building designs or modifications that met these dual goals regardless of occupant behaviour is a non-trivial task。 One way of approaching this problem that guarantees no grid connected energy usage is to use an off-grid PV-battery driven air-conditioner。 Here we use a detailed simulation model to investigate the suitability of a small off-grid PV-battery system to power an air-conditioner to provide occupant comfort for a range of different building thermal designs across Australian climates。 The relative importance of different building parameters on the ability of the off-grid system to provide comfort is discussed。 Results show that even in tropical climates, there are certain building thermal designs that lead to indoor temperatures <25 ◦C at all times with a modest size PV-battery system。74109

1。 Introduction

The creation of a comfortable thermal environment in which occupants can live and work is fundamental aspect of a building’s function。 A building that the occupants find comfortable leads to numerous well established flow-on benefits, for example in terms of liveability, contentedness, productivity and health  [1,2]。

At the same time, in Australia as in many countries the energy required to condition buildings is substantial fraction of the total electricity generated, and rising energy costs and the concern for greenhouse gas emissions are driving an increasing focus toward design of low energy consumption buildings。 This is evidenced for example by the adoption of more stringent minimum energy effi- cient building standards in legislation  [3]。

An additional factor is the impact of peak electricity con- sumption events that in most locations are driven largely by vapour-compression air-conditioner usage, typically on  only  a few hot days of the year。 Meeting peak consumption demand contributes substantially to the overall electricity network cost with  end-consumers  who  don’t  use  air-conditioning    effectively

cross-subsidising those who do to an estimated present value of

$300 M–500 M dollars annually [4]。 While both overall and peak consumption have recently declined from a high in 2009, both are projected to recover and rise steadily in the period to 2018–19 [5]。 The recent reduction in overall electricity consumption (and continuing reduction in per capita consumption) can be attributed to various factors including increasing appliance energy efficiency [6,7], increasing retail prices [8], greater awareness of and con- cern for reducing energy consumption and, in particular, the rapid uptake of residential and commercial solar photovoltaics (PV) [5]。 However, although distributed PV has reduced total energy con- sumption, its impact on peak consumption has been much less evident。 In Australia increasing PV uptake has resulted in the peak summer demand shifting to later in the day since the peak in PV output occurs around the  middle  of  the  day。  This  has  resulted in a decrease in the ratio of  average  grid  electricity  consump- tion to peak consumption in all states except NSW where PV uptake has been lower [5]。 This highlights the fact that while PV output responds almost instantaneously to radiation loads, build- ing air-conditioning (cooling) requirement is governed firstly by occupancy, and secondly lags substantially behind solar radiation because of the building thermal mass and non-radiative component

上一篇:酒店管理系统英文文献和中文翻译
下一篇:数控技术和装备发展趋势英文文献和中文翻译

兰州某大酒店空调设计+CAD图纸

新能源空调系统设计英文文献和中文翻译

太阳能热泵集热器英文文献和中文翻译

超市空调系统英文文献和中文翻译

南京某软件园研发楼空调系统设计

上海某商业中心暖通空调系统设计开题报告

中央空调系统设计英文文献和参考文献

ASP.net+sqlserver企业设备管理系统设计与开发

我国风险投资的发展现状问题及对策分析

安康汉江网讯

麦秸秆还田和沼液灌溉对...

互联网教育”变革路径研究进展【7972字】

LiMn1-xFexPO4正极材料合成及充放电性能研究

张洁小说《无字》中的女性意识

老年2型糖尿病患者运动疗...

网络语言“XX体”研究

新課改下小學语文洧效阅...