X 方向上自桩内边缘到最近柱边的水平距离:
ay = 880 - 0.5bc - 0.5bp = 880-700/2-433/2 = 313mm
λy = ay / ho = 313/(900-110) = 0.397
βy = 1.75 / (λy + 1.0) = 1.75/(0.397+1.0) = 1.253
βhs * βy * ft * bxo * ho = 1*1.253*1.43*2170*790 = 3078124N
≥ Vx = 1476000N,满足要求。
(3)、Y方向斜截面受剪承载力计算:
扣除承台及其上填土自重后 Y 方向斜截面的最大剪力设计值:
Vy = Max{N2 , N3} = 1476000N
承台斜截面受剪承载力按下列公式计算:
Vy ≤ βhs * βx * ft * byo * ho (基础规范 8.5.18-1)
Y 方向上自桩内边缘到最近柱边的水平距离:
ax = 750 - 0.5hc - 0.5bp = 750-800/2-433/2 = 133mm
λx = ax / ho = 133/(900-110) = 0.169
当 λx < 0.3 时,取 λx = 0.3
βx = 1.75 / (λx + 1.0) = 1.75/(0.3+1.0) = 1.346
βhs * βx * ft * byo * ho = 1*1.346*1.43*2320*790 = 3535272N
≥ Vy = 1476000N,满足要求。
4、柱下局部受压承载力计算:
局部荷载设计值 F = 4428000N
混凝土局部受压面积 Al = bc * hc = 560000mm
承台在柱下局部受压时的计算底面积按下列公式计算:
Ab = (bx + 2 * c) * (by + 2 * c)
c = Min{Cx, Cy, bx, by} = Min{850,810,800,700} = 700mm
Ab = (800+2*700)*(700+2*700) = 4620000mm
βl = Sqr(Ab / Al) = Sqr(4620000/560000) = 2.872
ω * βl * fcc * Al = 1.0*2.872*0.85*14.33*560000 = 19594014N
≥ F = 4428000N,满足要求。
5、桩局部受压承载力计算:
局部荷载设计值 F = Nmax + γg * Qgk = 1476+1.35*65.9 = 1564.9kN
混凝土局部受压面积 Al = π * d ^ 2 / 4 = 196350mm
承台在角桩局部受压时的计算底面积按下列公式计算:
Ab = (bx + 2 * c) * (by + 2 * c)
圆桩 bx = by = Sqr(Al) = 443mm
c = Min{Cx, Cy, bx, by} = Min{250,250,443,443} = 250mm
Ab = (443+2*250)*(443+2*250) = 889463mm
βl = Sqr(Ab / Al) = Sqr(889463/196350) = 2.128
ω * βl * fcc * Al = 1.0*2.128*0.85*14.33*196350 = 5090815N
≥ F = 1564899N,满足要求。
7.5.3 柱下独立承台:CT-3
工程名称:工程三
7.3 四桩承台简图
一、基本资料:
承台类型:四桩承台 圆桩直径 d = 500mm 六层现浇钢筋混凝土框架结构员工培训中心建筑与结构设计(77):http://www.youerw.com/gongcheng/lunwen_210.html